Clinical Laboratory Services

Test

Clinical Laboratory Services

Mediscan offers a one-stop solution for all clinical and pre-clinical laboratory services, providing the most accurate diagnostic results.
We have been touted as a centralised hub of diagnostic tests. We offer a complete spectrum of services for infectious diseases, cancer, blood glucose / CBP, hormonal assays, therapeutic drug assays, etc., and more to support physicians’ decisions and drive quality and efficiency.

Our highly qualified team of professionals and representatives work with you to provide relevant and on-time results, tailoring to your requirements. They also undergo periodic training programs to keep themselves updated in knowledge and gain new skills in their respective field.

We have world-class expertise with highly specialised and automated equipment to support our commitment to exceptional quality and accurate, error-free results. Our strong legacy of excellence has earned us the trust of patients, healthcare professionals and hospitals.
Every discipline of trained technical staff and microbiologist professionals is guided and supervised by well-experienced medical doctors. Approved test methodologies follow all investigations. Implementing automated equipment helps us to achieve great results while eliminating any chance of human error.

We offer a complete spectrum of services from routine tests such as CBP or Blood Glucose to highly specialized investigations for infectious diseases, cancer markers, hormonal assays, therapeutic drug assaya etc.

Each individual discipline is headed by experienced, professionally qualified Medical Doctors supported by a team of qualified and trained technologists.

All quantitative investigations are undertaken on fully automated state of art analyzers, which eliminate the chance of any human error.

Our Facilities

We Offering Healthcare Services to Client's

CLINICAL BIOCHEMISTRY

The lab is equipped with :

1. Two fully automated random access biochemistry analyzers, Ortho Clinical Diagnostic Vitros 250 approved by IVD and FDA.
LIS is in compliance with 21 CFR Part 11.

2. LIS is in compliance with 21 CFR Part 11.

3. Cobas E411 - fully automated random access hormone and tumor marker analyzer based on latest Electro Chemiluminiscence technology.

4. HPLC machine from Bio-Rad for Glycated Haemoglobin.(HBA1c). This is the state of the art technology for accurate estimation of Glycated haemoglobin and for screening for Abnormal haemoglobins.

5. Use of all closed channel equipments thereby ensuring use of standard reagents and quality of results.

CLINICAL PATHOLOGY


The lab is equipped with :

1. An automated Random Access Urine analyzer.

2. Screening for drugs of abuse.

The laboratory has two levels of Quality control measures in the department :

- Two level Internal Quality control samples run with every batch.

- Inter Laboratory Quality Assurance Programs - ILQA.

- Regular Internal audits to monitor out of control situations.

HEMATOLOGY


The lab is equipped with :

1. Two fully automated random access five part cell counters from Beckmen Coulter, working on the principle of flow cytometry.

2. Coagulometer for PT, APTT & Lupus anticoagulant assays & Thrombophilia profile.

3. D-Dimer & vWF assays on ELFA technology and G6PD assays.

4. Abnormal Hemoglobin screening on HPLC machine - D-10 Biorad.

5. Coagulation Factor assays on automated coagulometer.

The laboratory has three levels of Quality control measures in the department :

- Three level Internal Quality control measures with strict adherence to Westgard rule.

- Inter Laboratory Quality Assurance Programs - ILQA.

- External Quality Assurance Program (EQAS) - CMC Vellore & AIIMS, New Delhi.

- The lab is equipped with 3 part, 5 part haematology analyser, semi automated coagulation analyser.

- Regular Internal audits to monitor out of control situations.

-  Retesting of retained samples and replicate analysis.

-  Accuracy, Precision, uncertainty of measurement and Total error estimation and monitoring.

IMMUNOLOGY


The lab is equipped with :

1. Demonstrate how the ELISA assay is used to diagnose exposure to a disease by testing for the presence of antibodies to the disease in a sample of simulated serum.

2. Determine the hemagglutinating antibody titer of two different sera.

3. Demonstrate complement mediated lysis and the sequence of reactions necessary to cause lysis.

4. Centrifuges, thermal water baths

5. Protein electrophoresis and blotting system (Mini-PROTEAN®, BioRad)

6. ELISA reader

7. ELISPOT automated reader (Immunospot)

8. Modern visible light and fluorescent microscopes

9. Ultra-pure water system

10. Shuttles and a shake-incubator (Heidolph)

SEROLOGY & MICROBIOLOGY

The lab is equipped with :

The lab is well equipped and has the following facilities, which ensure we deliver the best results:
1. Automated ELISA system to perform tests on 50 different samples.

2. Automated culture, identification and sensitivity system to analyse aerobic and anaerobic bacteria.

3. Automated culture system for blood tests.

4. Immunofluorescence technology to detect autoimmune diseases.

5. Special tests such as Western blot for HIV, Quantiferon TB gold test, and ANA profile.

6. Complete allergy panel test to examine food and inhalation allergens.

The laboratory has three levels of quality control measures that are strictly followed in the department :

- ATCC strains are used to ensure complete quality control.

- Three-level Internal Quality control measures that strictly follow the CLSI guidelines.

- Inter Laboratory Quality Assurance Programs - ILQA to get the best data and analysis methods.

- External Quality Assurance Program (EQAS)
- IAMM Chennai.

- Regular Internal audits to monitor the safety of the infrastructure.

HISTOPATHOLOGY


The lab is equipped with :

1. In-house processing of histopathology samples.

2. In-House facility for Tru-cut biopsies.

3. Special stains - PAS, Alcian Blue, Methenamine Silver stain, Perl's stain, Congo Red stain.

4. Immuno histochemistry Markers - ER, PR, Her-2 neu, Cytokeratin, LCA, EMA & S-100.

5. Clones of standard strains and FDA approved companies are used.

6. Well trained and qualified pathologists with expertise in Oncopathology reporting.

7. Faster TAT.

The laboratory has three levels of Quality control measures in the department :

- Two level Internal Quality Control samples run with every batch of stains.

- Inter Laboratory Quality Assurance Programs - ILQA.

- Regular Internal audits to monitor out of control situations.